current location:home pageProduct Center

64504(F63P1) 64604(F63P3)

Instructions Download>

Model

F63P1/P364504/64604

Regeneration

Time clock type / meter type

Mount type

Top mount

Inlet/outlet

1"M

Drain

1/2"M

Brine line connector

3/8"M

Mounting base

2.5"-8NPSM

Riser pipe

1.05"OD

Flow rate

4m3/h

Filter tank

6"--18"

Water pressure

0.15-0.6Mpa

Water temperature

5-50℃

Water turbidity

Down-flow regeneration5FTU

Power adapter

Input AC100~240V/50~60HZ Output DC12V/1.5A

Application

Ion exchange equipment, water treatment system, undefinedRO pretreatment system


Product description

F63P Automatic Multiport Softener Valves

This simple meter type softener valve features a flow rate of 4m3/h. It adopts a planar and corrosion resistant gasket for opening and closing. Service, backwash, brine and slow rinse, brine refill, and fast rinse functions can be carried out with this valve. The F63P1 is a timer clock type while F63P3 is a meter type.

Product Characteristics

  • Simple structure and reliable sealing

    It adopts hermetic head faces with high degree pottery and corrosion resistance for opening and closing. It combines with Service, Backwash, Brine & Slow Rinse, Brine Refill and Fast Rinse for softener or Service, Backwash and Fast Rinse for filter.

  • No water pass the valve in regeneration in single tank type.

  • Manual function

    Realize regeneration immediately by pressing " Manual/Return" at any time.

  • Long outage indicator

    If outage overrides 3 days, the time of day indicator “12:12” will flash to remind the people to reset new time of day. The other set parameters do not need to reset. The process will continue to work after power on.

  • The valve will automatically rotate for dozens of seconds after it is electrified

    After the valve is electrified, it will automatically rotate for dozens of seconds to turn back to the position when the electricity is cut off.

  • Buttons lock

    No operations to buttons on the controller within 1 minute, button lock indicator lights on which represent buttons are locked. Before operation, press and hold the “ Up”and“ Down” buttons for 5 seconds to unlock. This function can avoid incorrect operation.

  • Interval backwash times (Suitable for F68P/F69P)

    It could set up interval backwash times for F68P/F69P up-flow regeneration valve which means several times of services but one time of backwash. The setting of interval backwash time depends on the local water turbidity. (The lower the turbidity is, the longer of the interval backwash time can be set)

  • It can choose time clock type or meter type by program selection

    When all symbols light on, press and hold Menu/Confirm and Manual/Return buttons for 5 seconds to enter the menu of valve model selection. Please set the program type in accordance with the product type. (Time clock type by days or meter type) (Note: The meter type product has one flow meter and probe wire, but the time clock type doesn’t have).

  • Maximum interval regeneration days

    Under the situation of service reaching the setting days and the volume not yet, it could enter into regeneration process forcibly when current time is the same as regeneration time.

  • All parameters can be modified

    According to the water quality and usage, the parameters in the process can be adjusted.